S Series: 6kW to 18kW | |
| RATINGS FOR S SERIES BOOSTERS | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Gallons per Hour Delivery At Indicated Temperature Rise | |||||||||
| KW | BTU/HR | 40° F | 50° F | 60° F | 70° F | 80° F | 100° F | 120° F | 140° F |
| 6 | 20,480 | 60 | 48 | 40 | 34 | 30 | 24 | 20 | 17 |
| 9 | 30,700 | 90 | 72 | 60 | 52 | 45 | 36 | 30 | 26 |
| 12 | 40,950 | 120 | 96 | 80 | 69 | 60 | 48 | 40 | 34 |
| 15 | 51,200 | 151 | 120 | 100 | 86 | 75 | 60 | 50 | 43 |
| 18 | 61,400 | 181 | 145 | 120 | 103 | 90 | 72 | 60 | 52 |
| Booster Heater Model Numbers | ||||
|---|---|---|---|---|
| Single or Three Phase | Three Phase | |||
| KW | 208 Volts | 240 Volts | 480 Volts | Shipping Weight |
| 6 | SS206 | SS226 | SS466 | 70 |
| 9 | SS209 | SS229 | SS469 | 70 |
| 12 | SS2012 | SS2212 | SS4612 | 70 |
| 15 | SS2015 | SS2215 | SS4615 | 70 |
| 18 | SS2018 | SS2218 | SS4618 | 70 |
* 208V and 240V heaters are adaptable to either 1 or 3 phase electrical connection. Consult installation manual for instructions. | ||||